Basic Heat Flow
A fundamental principle of heat flow is that heat will always flow from a warm space or object toward one that is colder. When this principle is
applied to a dwelling, it is apparent that in the winter, heat necessary to maintain a comfortable environment tends to flow upward through the
roof/ceiling system, outward through the exterior walls and downward through the floor system. Conversely, in the summer, the flow of heat is
reversed since the dwelling's interior is kept cooler than the outside air. The rate at which heat is transferred, in either case, is a function
of the temperature difference between the inside and outside air and the types of materials it must pass through. Accordingly, the rate of heat
loss or gain through this natural transfer can be reduced by the proper selection of a dwelling's construction and insulating materials. There
are three methods by which the natural transfer of heat takes place: (1) conduction, (2) convection and (3) radiation.
Conduction - is the flow of heat directly through a solid
material. The measure of a conductor's efficiency is based on how rapidly heat moves through it. The better conductor a material is, the worse
insulator it is.
Convection - is the transfer of heat by a fluid, usually water
or air since they are readily available.
Radiation - is the transfer of heat by electromagnetic waves
such as heat generated by the sun.
Thermo-Siphoning - or convection looping is caused by warm air
movement in conventional (fiberglass) insulated walls. The rising warm air creates a current in the cavity, drawing away heated or cooled inside
air. Damaging condensation is formed when the cool and warm air meet.
Temperature - is a measure of the intensity of heat and not the
quantity or amount of heat that is present. Temperature is measured by degrees of heat on a definite scale such as a
thermometer.
Relative Humidity (RH) - is a measure of the amount of water
vapor in air and is stated as a percentage. The ratio of the amount of water vapor in the air as compared to the maximum amount the air can
contain at a specific temperature and atmospheric pressure. For instance, the air at 50 percent RH contains 1/2 the amount of vapor it could hold
at a given temperature and atmospheric pressure; at 100 percent RH it contains the maximum, and such air is said to be saturated. The temperature
at which saturation or 100 percent relative humidity occurs is called the dew point.
Thermal Inertia - is the term used when a material has the
ability to store heat and retards the transfer of heat loss or gain.
British Thermal Unit (BTU) - is a measure of the amount of heat
required to change the temperature of an object and is a common way of comparing fuels and insulating materials. A BTU is the amount of heat
required to raise the temperature of one (1) pound of water one (1) degree Fahrenheit.
Thermal Resistance (R) - is a property which indicates a
material's ability to resist the flow of heat and is given in units of square foot-hour-degree Fahrenheit per BTU. When "R" values are given,
they reflect ideal conditions and do not account for installation practices or techniques that are common in the field that result in a reduction
of "R" values.
Thermal Transmittance (U) - is a measure of the time rate of
heat flow (air to air) expressed in units of BTU per hour per square foot per degree Fahrenheit. This term is most often used in energy
conservation codes as an expression of the overall coefficient of heat transmission of an assembly of materials. The "U" values of materials
cannot be added as "R" values can. However, the sum of the "R" values of the individual components of an assembly of materials divided into one
(1) will give the "U" value of the assembly. It should be emphasized that the component "R" values must be added together first then divided into
one (1) to determine the "U" value. In the preceding example U = 1/R = 1/13.62 =0.07
Thermal Conductance (C) - is a measure of the amount of heat in
BTU's that will pass through one square foot of a material of any thickness each hour for each degree Fahrenheit difference in temperature on
opposite sides of the material.
Thermal Conductivity (K) - is the measure of the number of
BTU's that will pass through one (1) square foot of a material one (1) inch thick each hour for each degree Fahrenheit difference in temperature
on opposite sides of the material.
|
|
|
Clarion
Health Self Clean Air-Flow Systems
The advanced technology lets you take clean air for granted.
The patented system lets you forget about the advanced engineering that chemically eliminates pollutants and
germs, instead of trapping and accumulating them.
It keeps your A/C coil and system filter clean and
is an important part of our “EnergyWise Healthy Home”.
Maintain optimal airflow while eliminating or reducing:
Mold -Germs -Fumes
Allergens -Bacteria -Radon Gas
Toxins -Dust Mites -Smoke
Call for pricing - 1-866-612-6842
|
|
|